How RetainX Calculates Wall Pressure from Adjacent Footings and Line Loads

A building footing, a column footing, a fence or sound-wall foundation, or a crane rail behind a retaining wall pushes on the wall through the soil. The push isn't uniform: it starts at the depth of the load, peaks a little below it, and fades with depth. RetainX's Adjacent Load input calculates that pressure with Boussinesq theory and adds it to the wall design. This article explains what the input does, the equations behind it, how to choose between the active and at-rest options, and what each related warning means.

What does the Adjacent Load input do?

On the Loads tab, under Vertical Force on Wall, pick Strip Footing, Line Load or Square Footing. A strip footing or line load runs parallel to the wall, behind it. A square footing is a single footing, such as a column footing, behind the wall.

The sketch shows the load: a footing (with a stub wall or column when it's buried) or an arrow for a line load, with the distance from the stem dimensioned just above grade. A strip footing and a square footing look the same in section, so the square footing's load reads in lb rather than lb/ft. With Soil Loading checked, the orange curve on the back of the stem is the pressure the load puts on the wall, unfactored, labeled with its peak. It starts at the load's depth and fades toward the footing.

The resulting pressure is added everywhere the soil pressure is used:

Why not just enter it as a surcharge?

The usual shortcut is to swap a concentrated load for an equivalent uniform surcharge and apply it with Rankine or Coulomb theory. Spangler and Mickle, summarizing a decade of tests on cantilever walls at Iowa State, pointed out two problems with that: there's no rational way to pick the equivalent surcharge, and it puts a uniform pressure over the whole wall height when the real pressure is concentrated over a band below the load. Their measured pressures followed the shape of the Boussinesq elastic solution, which is what RetainX uses.

The Surcharge input is still the right tool for a load that covers the backfill broadly, like traffic or yard storage. Use Adjacent Load for footings and line loads, and don't enter the same load both ways.

What equations does RetainX use?

Depth \(z\) is measured down from the load, so a footing whose base is 2 ft below grade puts no pressure on the wall above that 2 ft. \(x\) is the distance from the back of the stem to the load, and \(k\) is 1 or 2 from the Wall Condition input.

Strip footing of width \(B\) carrying \(P\) per foot, so a bearing pressure \(q = P/B\):

\[ \sigma_h = k \, \frac{q}{\pi} \left( \beta - \sin\beta \, \cos 2\alpha \right) \]

\(\beta\) is the angle the footing subtends, seen from the point on the wall, and \(\alpha\) is the angle from vertical to the middle of \(\beta\). With \(k = 2\), this is the strip-load equation in the Caltrans Trenching and Shoring Manual, and RetainX reproduces its Appendix C tables exactly (for example, 237.49 psf at 1 ft depth for a 300 psf strip from the wall face to 6 ft out).

Line load \(Q\) per foot:

\[ \sigma_h = k \, \frac{2Q}{\pi} \, \frac{x^2 z}{\left(x^2 + z^2\right)^2} \]

RetainX integrates \(\sigma_h\) down the wall to get the force and the height where it acts. Both equations are closed form, so the calculation is as fast as the rest of the wall.

A 3,000 lb/ft strip footing, 2 ft wide, 2 ft from the back of the stem, with its base 2 ft below grade, on a 10 ft retained height. On the stem base it adds 835 lb/ft and 4,198 lb-ft/ft with k = 1, or twice that with k = 2. Active soil at 40 pcf alone gives 2,000 lb/ft and 6,667 lb-ft/ft.

Square footing carrying a total load \(P\). A single footing spreads its pressure in three dimensions, so RetainX uses Boussinesq's solution for a point load \(P\) at distance \(x\) from the wall, which depends on the soil's Poisson's ratio \(\nu\). On the wall directly opposite the load:

\[ \sigma_h = k \, \frac{P}{2\pi R^2} \left[ \frac{3 z x^2}{R^3} - \frac{R \, (1 - 2\nu)}{R + z} \right], \qquad R = \sqrt{x^2 + z^2} \]

With \(k = 2\), this is AASHTO's equation for a point load on a wall restrained from movement (Article 3.11.6.2). RetainX divides the footing into a grid of 1,024 equal point loads, uses the full form of the equation for the loads off to the side, and adds them up on the section of wall directly opposite the footing's center. That's where the pressure is highest, and RetainX applies it to the whole foot of wall being designed. In reality the pressure fades along the wall on either side of the footing, so this is conservative.

A higher Poisson's ratio gives a higher pressure, and 0.5 gives the most. 0.3 is a typical value for sand and gravel backfill, and saturated clay is close to 0.5. Near the surface, a low ratio can make the equation go negative, which would mean the soil pulling on the wall. RetainX counts that as zero.

A 20,000 lb square footing, 4 ft on a side, 2 ft from the back of the stem, with its base 2 ft below grade, on the same 10 ft wall. On the stem base it adds 466 lb/ft and 2,289 lb-ft/ft with k = 1 and \(\nu = 0.3\), or 677 lb/ft and 3,405 lb-ft/ft with \(\nu = 0.5\). k = 2 doubles either.

Should I pick Active or At-Rest?

Boussinesq's equations give the stress inside an unbroken mass of soil. A wall cuts that mass, and the published guidance splits on how much the wall's stiffness matters:

AASHTO draws the same line, with separate provisions for walls restrained from movement and for flexible walls. Practitioners still disagree about where a typical cantilever wall falls.

A reasonable rule: if you designed the wall for active pressure because it's free to rotate or slide slightly, use Active. If it's restrained, for example braced at the top, a basement wall, or designed with the At-Rest analysis type, use At-Rest. When in doubt, At-Rest is the conservative choice.

Why is this so much larger than the Surcharge input?

The two inputs come from different theories, and they don't agree. The Surcharge input multiplies the surcharge by the active coefficient: a 250 psf surcharge with \(K_a = 0.33\) gives 83 psf on the wall. The elastic method gives \(k \cdot q/2\) for a load that covers the whole backfill from the wall outward: 125 psf with k = 1, and the full 250 psf with k = 2.

The active coefficient assumes the soil behind the wall has moved enough to reach failure, and the elastic solution assumes it hasn't. For a concentrated load close to the wall, the elastic pattern matches the tests above. For a broad, distant surcharge, the active method is the standard approach. Expect the Adjacent Load to govern more often than an equivalent surcharge would.

Where is the distance measured from?

From the back face of the stem's base section, for both the stem design and the overturning, sliding and bearing checks. For stability, measuring from the back of the heel would put the load farther away, so using the stem is the conservative choice. On a two-segment wall, the top segment's thinner back face is that much farther from the load, and RetainX uses its own distance there.

RetainX never counts the load's own weight as resisting overturning or sliding, even when the footing sits over the heel.

What load factor is used?

The adjacent load's pressure is treated as lateral earth pressure (H), the same as the soil and surcharge pressures, so it's factored by 1.6 in every load combination for the stem design. Overturning, sliding and bearing use it unfactored, like the other lateral loads.

What do the warnings mean?

Each Adjacent Load warning appears under Design Issues and links back to this article.

What isn't covered?

References